HP-CZY-5S持粘性測(cè)試儀設(shè)計(jì)標(biāo)準(zhǔn)
CNS-11887、11888、PSTC-7,GB/T 4851
HP-CZY-5S持粘性測(cè)試儀技術(shù)參數(shù)
溫 度: 常溫
試驗(yàn)治具: 5組
砝 碼: 1KG(或指定)
計(jì) 時(shí) 器: 5組,99999.9小時(shí)
試驗(yàn)鋼板: 5片
加載鋼板: 5片
外型尺寸: (L×W×H) 530×250×650 mm
機(jī)臺(tái)重量: 32kg
HP-CZY-5S持粘性測(cè)試儀又叫膠帶保持力試驗(yàn)機(jī),將膠帶粘于試驗(yàn)板上, 下端懸掛標(biāo)準(zhǔn)荷重,經(jīng)一段時(shí)間后, 測(cè)量膠帶下滑距離或膠帶粘著時(shí)間用來評(píng)定膠帶粘著的持久性。
設(shè)計(jì)標(biāo)準(zhǔn)
CNS-11887、11888、PSTC-7,GB/T 4851
技術(shù)參數(shù)
溫 度: 常溫
試驗(yàn)治具: 5組
砝 碼: 1KG(或指定)
計(jì) 時(shí) 器: 5組,99999.9小時(shí)
試驗(yàn)鋼板: 5片
加載鋼板: 5片
外型尺寸: (L×W×H) 530×250×650 mm
機(jī)臺(tái)重量: 32kg
HP-CZY-5S持粘性測(cè)試儀又叫膠帶保持力試驗(yàn)機(jī),將膠帶粘于試驗(yàn)板上, 下端懸掛標(biāo)準(zhǔn)荷重,經(jīng)一段時(shí)間后, 測(cè)量膠帶下滑距離或膠帶粘著時(shí)間用來評(píng)定膠帶粘著的持久性。
設(shè)計(jì)標(biāo)準(zhǔn)
CNS-11887、11888、PSTC-7,GB/T 4851
技術(shù)參數(shù)
溫 度: 常溫
試驗(yàn)治具: 5組
砝 碼: 1KG(或指定)
計(jì) 時(shí) 器: 5組,99999.9小時(shí)
試驗(yàn)鋼板: 5片
加載鋼板: 5片
外型尺寸: (L×W×H) 530×250×650 mm
機(jī)臺(tái)重量: 32kg
HP-CZY-5S持粘性測(cè)試儀又叫膠帶保持力試驗(yàn)機(jī),將膠帶粘于試驗(yàn)板上, 下端懸掛標(biāo)準(zhǔn)荷重,經(jīng)一段時(shí)間后, 測(cè)量膠帶下滑距離或膠帶粘著時(shí)間用來評(píng)定膠帶粘著的持久性。
設(shè)計(jì)標(biāo)準(zhǔn)
CNS-11887、11888、PSTC-7,GB/T 4851
技術(shù)參數(shù)
溫 度: 常溫
試驗(yàn)治具: 5組
砝 碼: 1KG(或指定)
計(jì) 時(shí) 器: 5組,99999.9小時(shí)
試驗(yàn)鋼板: 5片
加載鋼板: 5片
外型尺寸: (L×W×H) 530×250×650 mm
機(jī)臺(tái)重量: 32kg
概述:
KK5018系列過程信號(hào)校驗(yàn)儀是為高精度、多功能校準(zhǔn)熱工儀表而設(shè)計(jì)的校驗(yàn)儀表,能用來測(cè)量和輸出多種信號(hào),主要應(yīng)用于工業(yè)現(xiàn)場(chǎng)和實(shí)驗(yàn)室信號(hào)的測(cè)量和校準(zhǔn),是測(cè)試和校驗(yàn)工業(yè)自動(dòng)化系統(tǒng)及儀表必備的工具。主要在儀表車間、計(jì)量室、校準(zhǔn)實(shí)驗(yàn)室使用,滿足對(duì)各種熱工儀表的檢定、校準(zhǔn)及維護(hù)的需要。 KK5018系列過程信號(hào)校驗(yàn)儀支持電壓、電流、電阻、頻率、熱電偶、熱電阻、壓力等多種信號(hào)類型,精確度 0.01 %。 KK系列過程信號(hào)校驗(yàn)儀具有兩路獨(dú)立的測(cè)量、測(cè)量 / 輸出通道,顯示屏幕可同時(shí)查看測(cè)量和輸出,并有多種產(chǎn)品系列可供選擇。
主要功能與特點(diǎn):
◇精度等級(jí)±0.01%; ±0.02%;±0.05%三種精度可供選擇◇六位顯示:電流分辨率達(dá)0.1μA ;電壓分辨率達(dá)0.1μV◇測(cè)量直流電壓、電流、豪伏、2/3/4線制熱電阻、14種熱電偶、頻率和電阻等信號(hào)◇輸出/模擬電壓、電流、熱電阻、熱電偶、頻率、電阻信號(hào),可測(cè)試/校準(zhǔn)變送器◇4~20mA配電/回路,可在測(cè)試期間為變送器供電◇DC24V獨(dú)立供電◇自動(dòng)三角波/階梯波/正弦波信號(hào)輸出精度高達(dá)0.01%◇高穩(wěn)定性,溫漂低至3x10-6/℃◇具有交流/直流供電功能◇超大容量內(nèi)置可充鋰電池,更長工作時(shí)間,并可在線充電◇電池容量指示,電池電壓過低自動(dòng)關(guān)機(jī)◇溫度值可直接測(cè)量/輸出◇手/自動(dòng)冷端補(bǔ)償和設(shè)定◇零點(diǎn)量程自校準(zhǔn)◇點(diǎn)陣液晶顯示,界面友好,操作簡(jiǎn)便◇數(shù)字硅膠按鍵,操作更簡(jiǎn)便
系列產(chǎn)品
KK5018 多功能過程校驗(yàn)儀:精度: 0.01 級(jí), 0.02 級(jí), 0.05 級(jí);可測(cè)量 / 輸出電壓、電流、電流環(huán)、頻率、模擬電阻、毫伏、多種熱電阻和熱電偶等多種信號(hào),還可選配壓力模塊。
KK5016 熱電阻校驗(yàn)儀:精度 0.01 級(jí), 0.02 級(jí), 0.05 級(jí);可測(cè)量 / 輸出模擬電阻和多種熱電阻等信號(hào)。
KK5015 熱電偶校驗(yàn)儀:精度 0.01 級(jí), 0.02 級(jí), 0.05 級(jí);可測(cè)量 / 輸出毫伏和多種熱電偶等信號(hào)。
KK5014 壓力校驗(yàn)儀:電測(cè)部分精度: 0.01 級(jí), 0.02 級(jí), 0.05 級(jí);可測(cè)量 / 輸出電壓、電流等多種信號(hào);壓力部分精度: 0.025 級(jí), 0.05 級(jí), 0.1 級(jí),需要選配壓力模塊。壓力量程: -0.1MPa~260MPa 之間任意選擇。
KK5013 多功能回路校驗(yàn)儀:精度: 0.01 級(jí), 0.02 級(jí), 0.05 級(jí);可測(cè)量 / 輸出直流電壓、電流、電流環(huán)等多種信號(hào)。
技術(shù)指標(biāo):
| 名稱 | 測(cè)量端 | 測(cè)量 / 輸出端 | |
| 功能 | 測(cè)量 | 測(cè)量 | 輸出 |
| 直流電壓 DC V | 0 ~ 30V | 0 ~ 20V | 0 ~ 10V |
| 直流電壓 DC mV | 0 ~ 100mV | 0 ~ 100mV | |
| 直流電流 DC mA | 0 ~ 24mA |
| 0 ~ 24mA |
| 模擬變送器 |
|
| 0 ~ 24mA |
| 頻率 |
| 1 ~ 20KHz | 1 ~ 20KHz |
| 電阻 |
| 0 ~ 3200 Ω | 15 ~ 3200 Ω |
| 熱電偶 | J , K , T , E , U , B , R , S , L , N | ||
| 熱電阻 |
| Pt 100 Pt 200 Pt 500 Pt 1000 Pt 3926 Pt 3916 Cu50 Cu100 Ni120 | |
| 其他功能 | 自動(dòng)或手工設(shè)定冷端, 電流環(huán),階梯輸出,斜坡輸出,分屏顯示,保存用戶設(shè)置等 | ||
選型參考表
| 類型 / 型號(hào) | KK5018 | KK5016 | KK5015 | KK5014 | KK5013 | KK5012 |
| 電壓 | * |
|
| * | * | * |
| 電流 | * |
|
| * | * | * |
| 毫伏 | * |
| * |
| * | * |
| 電阻 | * | * |
|
|
|
|
| 頻率 | * |
|
|
| * |
|
| 熱電阻 | * | * |
|
|
|
|
| 熱電偶 | * |
| * |
|
|
|
| 正弦波 | * |
|
|
|
|
|
| 步進(jìn) / 階躍 | * | * | * | * | * | * |
| 計(jì)數(shù)保持 | * |
|
|
|
|
|
| 壓力模塊 | * |
|
| * |
|
|
| 232 接口 | * | * | * | * | * | * |
| 精度等級(jí) | T: ± 0.01%; C: ± 0.02%; G: ± 0.05% | |||||
| 24VDC 配電 | * | * | * | * | * | * |
說明:“ * ”為該型號(hào)儀表應(yīng)具有的功能?瞻讋t不具備。具體功能以電話洽詢?yōu)闇?zhǔn)。
KK5018應(yīng)用示例
| 1.模擬4~20MA變送器輸出 | 2.校準(zhǔn)紙帶/無紙記錄儀 |
![]() | ![]() |
| 3.模擬熱電偶的連接圖 | 4.校準(zhǔn)壓力電流(P/I)變送器 |
![]() | ![]() |
| 5.3線制熱電阻測(cè)量 | 6.校準(zhǔn)電流---電流(P/I)變送器 |
![]() | ![]() |
| 7.校準(zhǔn)熱電偶變送器 | 8.測(cè)量壓力的連接 |
![]() | ![]() |
數(shù)字直流電壓電流表 產(chǎn)品型號(hào): CJ5035B 工作電源: DC5V(共地) DC9V(隔離) AC/DC5-24V可選 基本量程: DC 200mV-500V DC 200uA-5A(直接輸入) 配交流互感器可測(cè)5A-2000A 配直流分流器可測(cè)5A-2000A 顯示字高:高16mmLCD顯示 最大顯示: 1999 精確度: ±(0.2%+2個(gè)字) 外形尺寸: 79×42×25 mm 開孔尺寸: 75×39 mm 產(chǎn)品特點(diǎn): LCD顯示,微功耗,可加背光工作。
*關(guān)鍵應(yīng)用:水泥粉料,塑料粉末/顆粒,谷物,煤倉,木屑,飛灰
~~~如有需要,請(qǐng)加QQ:2855668274(邁準(zhǔn)武漢辦小徐)
(★)煙囪新建工程:各種煙囪圖紙?jiān)O(shè)計(jì)、磚煙囪新建、磚煙囪砌筑高度65m以內(nèi),各種高度的磚煙囪圖紙?jiān)O(shè)計(jì)及建筑施工。各種高度的水泥煙囪滑模、移模、到模施工。 (★)煙囪拆除加高:煙囪口徑偏大或煙囪口徑偏小,煙囪砌筑高度不夠,煙囪上部傾斜等情況導(dǎo)致煙囪排風(fēng)不高空暢、倒煙現(xiàn)象、不符合環(huán)保要求、嚴(yán)重消耗能源等必須改造煙囪是十分理想的施工方案(我公司運(yùn)用不停產(chǎn)、無腳手架進(jìn)行煙囪加高、擴(kuò)縮煙囪口徑、煙囪上部傾斜嚴(yán)重、把煙囪傾斜部份進(jìn)行拆除、重新砌筑恢復(fù))。 (★)煙囪內(nèi)壁清灰及探傷檢查:煙囪多年運(yùn)行使用,煙囪內(nèi)壁灰塵積聚在煙囪內(nèi)壁上,多年的使用,使煙囪內(nèi)壁積灰增厚,嚴(yán)重影響煙囪的抽風(fēng)力。煙囪必須進(jìn)行定期內(nèi)壁清灰及煙囪內(nèi)壁探傷檢查(煙囪內(nèi)壁清灰、采用高空懸掛作業(yè)、進(jìn)行煙囪內(nèi)壁清灰及煙囪內(nèi)壁探傷檢查照相)。 (★)高空拆除工程:各種煙囪拆除、水塔拆除(人工拆除、定向拆除、爆破拆除),鐵塔拆除、尿素造粒塔拆除、電視塔拆除、鐵截架拆除,高空砼制框架拆除,及其它高難度高空拆除工程等。 (★)高空防腐工程:煙囪刷色環(huán)航標(biāo),煙囪刷涂料、煙囪刷油漆、煙囪寫字、煙囪粉刷、涼水塔防腐,鋼結(jié)構(gòu)防腐,爐架防腐,管道防腐保溫,風(fēng)力發(fā)電機(jī)塔筒防腐(清洗、噴字、維護(hù)),各種鐵塔防腐,煙囪防腐(平臺(tái)、爬梯、護(hù)網(wǎng)),儲(chǔ)油罐防腐,龍門吊防腐、賓館、大廈外墻刷涂料,吊機(jī)防腐等工程。 (★)高空安裝工程:煙囪安裝避雷針、航標(biāo)燈,信號(hào)燈,鋼煙囪安裝,煙囪安裝爬梯、安全平臺(tái)、安全護(hù)網(wǎng)、煙囪頂口云梯安裝及各種鐵塔安裝,廠房、車間玻璃安裝等。 (★)煙氣脫硫工程: 各類煙囪、煙道、脫硫塔內(nèi)壁粘貼泡沫玻璃磚、涂敷LS300特種耐酸膠泥、OM、聚尿、PV等煙囪專用脫硫防腐涂料的施工等系列工程。
K-562 人慢性髓原白血病細(xì)胞
ATCC® Number: CCL-243™ Designations: K-562 Depositors: HT Holden Biosafety Level: 1 Shipped: frozen Medium & Serum: See Propagation Growth Properties: suspension Organism: Homo sapiens (human) Morphology: lymphoblast
Source: Organ: bone marrow Disease: chronic myelogenous leukemia (CML) Permits/Forms: In addition to the MTA mentioned above, other ATCC and/or regulatory permits may be required for the transfer of this ATCC material. Anyone purchasing ATCC material is ultimately responsible for obtaining the permits. Please click here for information regarding the specific requirements for shipment to your location. Applications: transfection host (Nucleofection technology from Lonza) Tumorigenic: Yes Reverse Transcript: negative Antigen Expression: CD7 (25%) DNA Profile (STR): Amelogenin: X CSF1PO: 9,10 D13S317: 8 D16S539: 11,12 D5S818: 11,12 D7S820: 9,11 THO1: 9.3 TPOX: 8,9 vWA: 16 Cytogenetic Analysis: The stemline chromosome number is triploid with the 2S component occurring at 4.2%. Fifteen markers (M1 and M(15)) occurred in nearly all S metaphases. Spontaneous non-specific dicentrics occurred, but rarely. Unstable markers were also rarely seen. The X was disomic, and N9 was nullisomic. Isoenzymes: AK-1, 1 ES-D, 1 G6PD, B GLO-I, 2 Me-2, 0 PGM1, 0 PGM3, 1 Age: 53 years Gender: female Comments: The continuous cell line K-562 was established by Lozzio and Lozzio from the pleural effusion of a 53-year-old female with chronic myelogenous leukemia in terminal blast crises. [22609] The cell population has been characterized as highly undifferentiated and of the granulocytic series. [26059] Studies conducted by Anderson, et al., on the surface membrane properties led to the conclusion that the K-562 was a human erythroleukemia line. [26060] The K-562 cell line has attained widespread use as a highly sensitive in vitro target for the natural killer assay. [48829] [1101] [48830] See Pross, et al. for a detailed analysis of the in vitro assay of NK cells including the mathematics of quantitation of NK cell activity. [48833] K-562 blasts are multipotential, hematopoietic malignant cells that spontaneously differentiate into recognizable progenitors of the erythrocytic, granulocytic and monocytic series. [26061] The effect of inducers on sublines derived from the original K-562 cell line have been reviewed by Koeffler and Golde. [867] Cultures from the ATCC stock have been shown to exhibit this sensitivity for assessing human natural killer activity. Karyological studies on various K-562 sublines have been classified into three groups (A,B,C) by Dimery, et al. [26063] The strain obtained by the ATCC most closely resembles the B population. Occurrence of the Philadelphia chromosome, however, was of much lower frequency; none detected in 15 metaphases examined. The line is EBNA negative. Propagation: ATCC complete growth medium: The base medium for this cell line is ATCC-formulated Iscove's Modified Dulbecco's Medium, Catalog No. 30-2005. To make the complete growth medium, add the following components to the base medium: fetal bovine serum to a final concentration of 10%.Atmosphere: air, 95%; carbon dioxide (CO2), 5% Temperature: 37.0°C Subculturing: Protocol: Cultures can be maintained by the addition or replacement of fresh medium. Start new cultures at 1 X 10 exp5 viable cells/ml. Subculture at 1 X 10 exp6 cells/ml. Medium Renewal: Every 2 to 3 days Preservation: Freeze medium: Complete growth medium 95%; DMSO, 5% Storage temperature: liquid nitrogen vapor temperature Related Products: Recommended medium (without the additional supplements or serum described under ATCC Medium):ATCC 30-2005recommended serum:ATCC 30-2020purified DNA:ATCC CCL-243Dpurified RNA:ATCC CCL-243R References: 867: Koeffler HP, Golde DW. Human myeloid leukemia cell lines: a review. Blood 56: 344-350, 1980. PubMed: 69967651101: Ortaldo JR, et al. Specificity of natural cytotoxic reactivity of normal human lymphocytes against a myeloid leukemia cell line. J. Natl. Cancer Inst. 59: 77-82, 1977. PubMed: 6903622609: Lozzio CB, Lozzio BB. Human chronic myelogenous leukemia cell-line with positive Philadelphia chromosome. Blood 45: 321-334, 1975. PubMed: 16365826059: Lozzio BB, Lozzio CB. Properties and usefulness of the original K-562 human myelogenous leukemia cell line. Leuk. Res. 3: 363-370, 1979. PubMed: 9502626060: Andersson LC, et al. K562--a human erythroleukemic cell line. Int. J. Cancer 23: 143-147, 1979. PubMed: 36797326061: Lozzio BB, et al. A multipotential leukemia cell line (K-562) of human origin. Proc. Soc. Exp. Biol. Med. 166: 546-550, 1981. PubMed: 719448026063: Dimery IW, et al. Variation amongst K562 cell cultures. Exp. Hematol. 11: 601-610, 1983. PubMed: 657690932357: Chan YJ, et al. Two distinct upstream regulatory domains containing multicopy cellular transcription factor binding sites provide basal repression and inducible enhancer characteristics to the immediate-
K-562 人慢性髓原白血病細(xì)胞故障分析:修理此類故障首先要從供電線路切入,測(cè)量24v供電正常,單獨(dú)供24v電,球機(jī)沒有自檢反應(yīng),指示燈不亮,看來是內(nèi)部電路有問題了,檢測(cè)電源電路,發(fā)現(xiàn)串聯(lián)在24v供電上的溫控保護(hù)器處于常開狀態(tài),確定保護(hù)器損壞,更換后球機(jī)自檢正常,指示燈亮,但是主機(jī)與球機(jī)仍通訊不上,更換通訊芯片后,故障排除。
其他故障:
1、霍尼韋爾球機(jī)不通電,無圖像,指示燈不亮 檢查電源線是否接錯(cuò):如接錯(cuò)請(qǐng)按照正確的方法連接電源線。 檢查供電電源是否損壞:如電源損壞請(qǐng)更換確保未被損壞的供電電源。 檢驗(yàn)保險(xiǎn)管是否損壞:如有損壞請(qǐng)更換確保未被損壞的保險(xiǎn)管。 檢驗(yàn)電源線是否接觸不良:如接觸不良,請(qǐng)重新連接好電源線,或更換電源線。 2、霍尼韋爾球機(jī)通電有自檢,有圖像,不能控制 檢查球機(jī)地址碼、波特率設(shè)定是否有誤:如有誤請(qǐng)?jiān)O(shè)置相匹配的地址碼和波特率。 檢查協(xié)議設(shè)置是否正確:如有誤請(qǐng)?jiān)O(shè)置相對(duì)應(yīng)的協(xié)議。 檢查RS485控制線連接是否正確:如有誤請(qǐng)按照正確的方法連接。 3、霍尼韋爾球機(jī)自檢無法進(jìn)行,有圖像但伴有噪音 檢驗(yàn)是否機(jī)械故障:請(qǐng)修正球機(jī)內(nèi)部機(jī)械結(jié)構(gòu),如攝像機(jī)傾斜請(qǐng)擺正。 可能電源功率不夠:請(qǐng)更換符合要求的電源,盡量把開關(guān)電源放在球機(jī)附近。 4、霍尼韋爾球機(jī)圖像不穩(wěn)定 更換合格的視頻線,檢驗(yàn)是否視頻線接觸不良。 可能電源功率不夠:請(qǐng)更換符合要求的電源,并盡量把開關(guān)電源放在球機(jī)附近。 5、霍尼韋爾球機(jī)畫面模糊 可能聚焦為手動(dòng)狀態(tài),控制球機(jī)或調(diào)用任一預(yù)置位,球機(jī)可恢復(fù)自動(dòng)聚焦。 透明罩臟,清洗透明罩 6、霍尼韋爾球機(jī)控制不停或延遲 檢查控制最遠(yuǎn)處球機(jī)匹配電阻是否加入,在離控制遠(yuǎn)處的球機(jī)如未加入,請(qǐng)加入匹配電阻。 可能電源功率不夠:請(qǐng)更換符合要求的電源,并盡量把開關(guān)電源放在球機(jī)附近。
以上是我公司在維修的過程中總結(jié)出來的,深圳市視諾爾科技有限公司是一家專業(yè)的維修公司,霍尼韋爾球機(jī)維修是其中之一,我們自成立以來已經(jīng)成功維修了很多霍尼韋爾球機(jī),各種問題我們?nèi)缃穸寄苡卸,如有需要維修霍尼韋爾球機(jī)的歡迎您的咨詢!
http://www.jiankong-wx.com深圳安防監(jiān)控維修網(wǎng)站與維護(hù)網(wǎng)站